Safety Precautions for Cleaning the Machine

Cleaning agent

The machine must not be cleaned using substances that cause irritation or are harmful to health or the environment, such as chlorinated hydrocarbons (PER, TRI etc.).

Ensure that cleaning agents are disposed of in an environment friendly way.

Do not use cleaning devices

Under no circumstances should steam or water jets or compressed air be used for cleaning, as there is a risk of dirt or cleaning agents getting into the guideways or seals. This can impair the function of switching elements or measuring systems.

Remove swarf

Remove swarf with an appropriate tool such as a hand brush. Do not touch swarf with bare hands: wear suitable protective gloves.