Topping up Oil in the Lubrication UnitComponent Lubrication unit Action Topping up oil in the lubrication unit tank. The lubrication circuit is an open system. The useable capacity of the lubrication container is adequate for at least 400 operating hours. Lubrication oil CLP 68 acc. to DIN 51517, part 3 (ISO-L-CKC 68 acc. to ISO 6743, part 6) Purity class ISO 4406-18/16/13 Container capacity 6 l Disimilar lubricants can contain various additives that might not be compatible. To rule out incompatibility between the lubricants, disimilar lubricants must not be mixed.If you have any questions, please contact your lubricant supplier. For manufacturer's documentation on the lubrication unit, see Subsuppliers' Information (ZI) from "SKF" For structure of the central lubrication system, see Media Diagram (MP). Unscrew locking lid. Check the sieve in the filling opening for contamination and clean if necessary. Fill with oil through opening until the level reaches the maximum mark. Secure locking lid. |